/// This example demonstrates how to read values from the sensor and
/// continously send them to an influx database.
/// Make sure you adapt the influx constants and likely also the i2c device id and I2CAddress.
///
extern crate bme680;
extern crate embedded_hal;
extern crate env_logger;
extern crate linux_embedded_hal;
extern crate influent;
use bme680::*;
use embedded_hal::blocking::i2c;
use linux_embedded_hal::*;
use std::thread;
use std::time::Duration;
use influent::create_client;
use influent::client::{Client, Credentials};
use influent::measurement::{Measurement, Value};
const INFLUX_ADDRESS: &str = "http://127.0.0.1:8086";
const INFLUX_USER: &str = "user";
const INFLUX_PASSWORD: &str = "pass";
const INFLUX_DATABASE: &str = "influxdb";
type I2CResult = std::result::Result<(), Error<<I2cdev as i2c::Read>::Error, <I2cdev as i2c::Write>::Error>>;
fn main() -> I2CResult
{
// Init device
let i2c = I2cdev::new("/dev/i2c-1").unwrap();
let mut dev = Bme680::init(i2c, Delay {}, I2CAddress::Primary)?;
let settings = SettingsBuilder::new()
.with_humidity_oversampling(OversamplingSetting::OS2x)
.with_pressure_oversampling(OversamplingSetting::OS4x)
.with_temperature_oversampling(OversamplingSetting::OS8x)
.with_temperature_filter(IIRFilterSize::Size3)
.with_gas_measurement(Duration::from_millis(1500), 320, 25)
.with_run_gas(true)
.build();
dev.set_sensor_settings(settings)?;
// Set up Influx client
let credentials = Credentials {
username: INFLUX_USER,
password: INFLUX_PASSWORD,
database: INFLUX_DATABASE
};
let hosts = vec![INFLUX_ADDRESS];
let client = create_client(credentials, hosts);
loop {
dev.set_sensor_mode(PowerMode::ForcedMode)?;
let (data, state) = dev.get_sensor_data()?;
println!("State {:?}", state);
println!("Temperature {}°C", data.temperature_celsius());
println!("Pressure {}hPa", data.pressure_hpa());
println!("Humidity {}%", data.humidity_percent());
println!("Gas Resistence {}Ω", data.gas_resistance_ohm());
if state == FieldDataCondition::NewData {
send_value(&client, "temperature" ,Value::Float(data.temperature_celsius() as f64));
send_value(&client, "pressure" ,Value::Float(data.pressure_hpa() as f64));
send_value(&client, "humidity" ,Value::Float(data.humidity_percent() as f64));
send_value(&client, "gasresistence" , Value::Float(data.gas_resistance_ohm() as f64));
}
thread::sleep(Duration::from_millis(5000));
}
}
/// Sends a measured value to the influx database
fn send_value(client:&Client, type_name: &str, value: Value) {
let mut measurement = Measurement::new("sensor");
measurement.add_field("value", value);
measurement.add_tag("id", "MAC");
measurement.add_tag("name", "bme680");
measurement.add_tag("type", type_name);
client.write_one(measurement, None).unwrap();
}