using System;
using System.Collections.Generic;
using System.Device.I2c;
using System.Threading.Tasks;
using Microsoft.Extensions.Logging;
using Microsoft.Extensions.Options;
using Newtonsoft.Json;
using NucuCar.Sensors.Abstractions;
using Iot.Device.Bmxx80;
using UnitsNet;
using Bme680 = Iot.Device.Bmxx80.Bme680;
using Bme680PowerMode = Iot.Device.Bmxx80.PowerMode.Bme680PowerMode;
using Sampling = Iot.Device.Bmxx80.Sampling;
namespace NucuCar.Sensors.Modules.Environment
{
internal class Bme680MeasurementData
{
public double Temperature { get; set; }
public double Humidity { get; set; }
public double Pressure { get; set; }
public double VolatileOrganicCompounds { get; set; }
}
///
/// Abstraction for the BME680 sensor.
/// See: https://www.bosch-sensortec.com/bst/products/all_products/bme680
///
public class Bme680Sensor : GenericTelemeterSensor, IDisposable, ISensor
{
private I2cConnectionSettings _i2CSettings;
private I2cDevice _i2CDevice;
private Bme680 _bme680;
private Bme680MeasurementData _lastMeasurement;
public Bme680Sensor()
{
}
public Bme680Sensor(ILogger logger, IOptions options)
{
CurrentState = SensorStateEnum.Uninitialized;
Logger = logger;
if (!options.Value.Enabled)
{
Logger?.LogDebug("BME680 Sensor is disabled!");
CurrentState = SensorStateEnum.Disabled;
}
TelemetryEnabled = options.Value.Telemetry;
Object = this;
}
public override NucuCarSensorResponse GetMeasurement()
{
var jsonResponse = JsonConvert.SerializeObject(_lastMeasurement);
return new NucuCarSensorResponse
{
State = GetState(),
JsonData = jsonResponse
};
}
public override SensorStateEnum GetState()
{
return CurrentState;
}
public void Dispose()
{
_bme680?.Dispose();
}
public override void Initialize()
{
if (CurrentState == SensorStateEnum.Initialized || CurrentState == SensorStateEnum.Disabled)
{
return;
}
_lastMeasurement = new Bme680MeasurementData();
try
{
/* Connect to default i2c address 0x76 */
_i2CSettings = new I2cConnectionSettings(1, Bme680.DefaultI2cAddress);
_i2CDevice = I2cDevice.Create(_i2CSettings);
_bme680 = new Bme680(_i2CDevice);
/* Initialize measurement */
_bme680.Reset();
_bme680.TemperatureSampling = Sampling.HighResolution;
_bme680.HumiditySampling = Sampling.HighResolution;
_bme680.PressureSampling = Sampling.HighResolution;
_bme680.HeaterProfile = Bme680HeaterProfile.Profile2;
CurrentState = SensorStateEnum.Initialized;
Logger?.LogInformation($"{DateTimeOffset.Now}:BME680 Sensor initialization OK.");
}
catch (System.IO.IOException e)
{
HandleInitializationException(e);
}
catch (ArgumentException e)
{
HandleInitializationException(e);
}
}
public override async Task TakeMeasurementAsync()
{
if (CurrentState != SensorStateEnum.Initialized)
{
throw new InvalidOperationException("Can't take measurement on uninitialized sensor!");
}
_bme680.ConfigureHeatingProfile(Bme680HeaterProfile.Profile2,
Temperature.FromDegreesCelsius(280), Duration.FromMilliseconds(80),
Temperature.FromDegreesCelsius(_lastMeasurement.Temperature));
var measurementDuration = _bme680.GetMeasurementDuration(_bme680.HeaterProfile);
/* Force the sensor to take a measurement. */
_bme680.SetPowerMode(Bme680PowerMode.Forced);
await Task.Delay(measurementDuration.ToTimeSpan());
_bme680.TryReadTemperature(out var temp);
_bme680.TryReadHumidity(out var humidity);
_bme680.TryReadPressure(out var pressure);
_bme680.TryReadGasResistance(out var gasResistance);
_lastMeasurement.Temperature = Math.Round(temp.DegreesCelsius, 2);
_lastMeasurement.Pressure = Math.Round(pressure.Hectopascals, 2);
_lastMeasurement.Humidity = Math.Round(humidity.Percent, 2);
_lastMeasurement.VolatileOrganicCompounds = Math.Round(gasResistance.Kiloohms, 2);
Logger?.LogDebug($"{DateTimeOffset.Now}:BME680: reading");
Logger?.LogInformation(
$"temperature:{_lastMeasurement.Temperature:N2} \u00B0C|" +
$"pressure:{_lastMeasurement.Pressure:N2} hPa|" +
$"humidity:{_lastMeasurement.Humidity:N2} %rH|" +
$"voc:{_lastMeasurement.VolatileOrganicCompounds}");
}
public override string GetIdentifier()
{
return "Environment";
}
public override Dictionary GetTelemetryData()
{
Dictionary returnValue = null;
if (_lastMeasurement != null && TelemetryEnabled)
{
returnValue = new Dictionary
{
["sensor_state"] = CurrentState,
["temperature"] = _lastMeasurement.Temperature,
["humidity"] = _lastMeasurement.Humidity,
["pressure"] = _lastMeasurement.Pressure,
["voc"] = _lastMeasurement.VolatileOrganicCompounds
};
}
return returnValue;
}
public override bool IsTelemetryEnabled()
{
return TelemetryEnabled;
}
public Bme680Sensor Object { get; }
private void HandleInitializationException(Exception e)
{
Logger?.LogError($"{DateTimeOffset.Now}:BME680 Sensor initialization FAIL.");
Logger?.LogDebug(e.Message);
CurrentState = SensorStateEnum.Error;
}
}
}